Environmental Remediation &
Restoration Construction Safety
HAZWOPER-qualified safety professionals for brownfield redevelopment, Superfund site work, hazardous demolition, and environmental restoration. Specialized HASP documentation, air monitoring oversight, decontamination protocols, and worker exposure controls.

HAZWOPER-Qualified. EPA-Documentation Ready.
Every environmental safety professional we deploy carries current HAZWOPER 40-hour certification with annual 8-hour refresher. We verify currency before every deployment and maintain refresher records as part of our QA process.
Our site safety officers develop and manage HASPs per 29 CFR 1910.120, including hazard analysis, PPE selection, air monitoring action levels, decontamination procedures, and emergency response protocols. We maintain our own monitoring instrumentation.
Three Divisions for Regulated Environmental Work
Environmental construction requires HAZWOPER 40-hour qualified personnel with current refreshers, HASP-aware documentation, RCRA Subtitle C familiarity, and proven competence in air monitoring, decontamination, and worker exposure controls.
Crane Operator Training
NCCCO certification for operators working in contaminated environments. Emphasis on Level B/C PPE crane operation, equipment decontamination procedures, and exclusion-zone material handling for environmental sites.
- NCCCO Mobile Crane (TLL, LBC, TSS)
- PPE-encumbered operator training
- Exclusion-zone material handling
- Decontamination procedure familiarity
- Demolition crane operator focus
Safety Staffing
HAZWOPER Site Safety Officers, air monitoring technicians, and HASP managers for Superfund sites, brownfield construction, and hazardous waste remediation. Real-time exposure assessment and decontamination oversight.
- HAZWOPER 40-hour qualified SSHOs
- Air monitoring technicians
- HASP developers / managers
- Confined space rescue technicians
- EPA / state regulator liaison
Equipment Inspections
Crane and rigging inspections for contaminated-site operations — excavators with extended booms, material handling cranes, and demolition equipment working in exclusion zones. Pre-job inspections and exit decontamination verification.
- Contaminated-site equipment inspections
- Pre-job & post-job decontamination check
- Extended-boom excavator inspections
- Material handler rigging audits
- Demolition crane safety verification
Every Phase of Environmental Work
From characterized brownfield redevelopment to long-tail Superfund remediation, we deploy personnel matched to your site contaminants and EPA / state regulator expectations.
Brownfield Redevelopment
Construction on former industrial sites with known or suspected contamination. Soil and groundwater management, vapor intrusion mitigation.
Superfund / CERCLA Sites
EPA-regulated remediation and construction. Strict PPE zones, community air monitoring, long-term remedial action support, ROD alignment.
Hazardous Demolition
Structures with asbestos, lead paint, PCBs, or radiological contamination. Abatement oversight and demolition safety coordination.
Tank Removal & Closure
UST / AST removal, soil excavation, groundwater treatment system installation, and site closure documentation per state regulator.
Landfill Construction
Cell construction, liner installation, leachate system construction, cap placement, and methane management system safety.
Ecological Restoration
Wetland construction, stream restoration, sediment remediation, habitat reconstruction with heavy equipment and SWPPP.
HAZWOPER-Qualified Personnel
Every environmental safety professional we deploy carries current HAZWOPER 40-hour certification with annual 8-hour refresher. We verify currency before every deployment.
Regulatory & Documentation
- HAZWOPER 40-Hour (29 CFR 1910.120)
- HAZWOPER Annual 8-Hour Refresher
- RCRA Subtitle C Hazardous Waste
- HASP Development & Management
- EPA ROD & AUL coordination familiar
- Asbestos / Lead / PCB Awareness
- Community air monitoring documentation
Technical & Field
- Air Monitoring & Instrumentation
- Level A/B/C/D PPE Competent
- PID / FID / Particulate Operation
- Decontamination Procedure Development
- Confined Space Rescue Technician
- OSHA 30 Construction
- CHST / CSP Board Certified
Built for Regulated Remediation
Environmental remediation has unique documentation, agency, and exposure-control requirements. Here’s how we’re built for them.
Current HAZWOPER Bench
Every environmental safety professional carries current HAZWOPER 40-hour certification with annual 8-hour refresher. We verify currency before every deployment and maintain refresher records.
HASP Development
Our site safety officers develop and manage HASPs per 29 CFR 1910.120 including hazard analysis, PPE selection, air monitoring action levels, decontamination procedures, and emergency response protocols.
Regulator Interface
EPA, state regulator, and community air monitoring documentation expectations are met by personnel who’ve walked these sites before. We don’t learn the regulatory framework on your project.
Air Monitoring Capability
PID / FID operation, real-time particulate monitoring, personal air sampling pump management, perimeter monitoring stations, and action-level response. We maintain our own instrumentation.
Environmental Safety FAQ
Quick answers for environmental consultants, EPA-regulated site owners, and remediation contractors.
Yes. Every safety professional we deploy to environmental remediation projects holds current HAZWOPER 40-hour certification with annual 8-hour refresher. We verify current status before every deployment and maintain refresher records.
Yes. Our site safety officers develop and manage HASPs per 29 CFR 1910.120 requirements, including hazard analysis, PPE selection, air monitoring action levels, decontamination procedures, and emergency response protocols specific to your site contaminants.
Yes. We provide site safety officers experienced with EPA ROD requirements, community air monitoring obligations, regulatory agency interface, and the documentation standards required for long-term remedial action projects.
Our staff are trained in PID / FID operation, real-time particulate monitoring, personal air sampling pump management, perimeter air monitoring station operation, and action-level response protocols. We calibrate and maintain our own instrumentation.
Yes. Our environmental bench includes personnel familiar with asbestos, lead paint, PCB, and (in some cases) radiological contamination. We coordinate with licensed abatement contractors, oversee demolition safety, and document compliance with state and federal abatement requirements.
Yes. Our environmental crane operator bench includes NCCCO-certified operators with current HAZWOPER 40-hour training. We deploy operators who can work in Level B and C PPE for material handling in exclusion zones and demolition operations.
Hub for Sector-Specific Safety
3psafety.net is the central hub. Each industry page covers credentials, project types, and scope detail for that sector.
Serving All 50 U.S. States
3P Safety deploys credentialed safety professionals, NCCCO crane operators, and ASME B30 inspectors to every U.S. state — from corporate headquarters in Goldsboro, NC and four regional offices nationwide. No matter where your project is, we’re cleared, credentialed, and ready to mobilize within 48–72 hours.